Thermoworks IRFS INFRARED FOOD SAFETY THERMOMETER User Manual

Browse online or download User Manual for Measuring instruments Thermoworks IRFS INFRARED FOOD SAFETY THERMOMETER. ThermoWorks IRFS INFRARED FOOD SAFETY THERMOMETER User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
T
T
N
N
4
4
0
0
3
3
/
/
T
T
N
N
4
4
0
0
3
3
L
L
T
T
h
h
e
e
r
r
m
m
o
o
m
m
e
e
t
t
e
e
r
r
O
O
p
p
e
e
r
r
a
a
t
t
i
i
n
n
g
g
I
I
n
n
s
s
t
t
r
r
u
u
c
c
t
t
i
i
o
o
n
n
s
s
Model: TN403, TN403L (with Laser).
The thermometer is a non-contact infrared thermometer, and always with Real-Time Maximum (MAX) data.
Please remember to keep away from children and don’t use it for safety related applications.
(Default Screen)
ADD VALUE:
o
C or
o
F
Press Mode key (
2
) for
o
C or
o
F transferred.
:
LCD Backlight: always on.
:
ClassII Laser: always enable (only for TN403L)
EMC/RFI
Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of
approximately 3 volts per meter, but the performance of the instrument will not be permanently affected.
* Note: Under the electromagnetic field of 3V/m from 350 to 550MHZ, the maximum error is 8°C (14.4°F).
A new way to measure temperature
Radiant Innovation Inc. Http://www.ZyTemp.com
1F, No.3, Industrial East 9
th
Road, Science-Based Industrial Park,
HsinChu, Taiwan 300.
CAUTION
1. WHEN DEVICE IS IN USE, DO NOT LOOK DIRECTLY INTO THE LASER BEAM–PERMANENT EYE DAMAGE
MAY RESULT.
2. USE EXTREME CAUTION WHEN OPERATING THE LASER.
3. NEVER POINT THE DEVICE TOWARDS ANYONE’S EYES.
4. KEEP OUT OF REACH OF ALL CHILDREN.
STORAGE & CLEANING
The sensor lens is the most delicate part of the thermometer. The lens should be kept clean at all times, care should
be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol. Allowing the
lens to fully dry before using the thermometer. Do not submerge any part of the thermometer. The thermometer
should be stored at room temperature between –20 to +65°C (-4~149°F).
LCD ERROR MESSAGES
The thermometer incorporates visual diagnostic messages as follows:
‘Er2’ is displayed when the thermometer is exposed to rapid changes in the ambient temperature.
‘Er3’ is displayed when the ambient temperature exceeds 0
o
C(32°F) or +50
o
C (122°F).
The thermometer should be allowed plenty of time (minimum 30 minutes) to stabilize to the
working/room temperature.
For all other error messages it is necessary to reset the thermometer. To reset it, turn the
instrument off, remove the battery and wait for a minimum of one minute, reinsert the battery and
turn on. If the error message remains please contact the Service Department for further
assistance.
BATTERIES
The thermometer incorporates visual low battery indication as follows:
‘Battery OK’: measurements
are possible
‘Battery Low’: battery needs to be
replaced, measurements are still possible
‘Battery Exhausted’: measurements
are not possible
When the ‘Low Battery’ icon indicates the battery is low, the battery should be replaced immediately with AAA,
1.5V batteries. Please note: It is important to turn the instrument off before replacing the battery otherwise the
thermometer may malfunction.
Dispose of used battery promptly and keep away from children.
SPECIFICATION
Model TN403, TN403L (with Laser)
Measurement Range
-60 to +500
o
C (-76 to +932
o
F)
Operating Range 0~50°C (32~122°F)
Accuracy, (Tobj=15-35°C,Tamb=25°C) +/-1.0°C (1.8°F)
Accuracy
(Tobj=-33-500°C,Tamb=23 +/- 3°C)
+/-2% of reading or 2°C (4°F) whichever is greater
Emissivity 0.95 fixed
Resolution (-9.9~199.9°C) 0.1°C/0.1°F
Response Time (90%) 1sec
Distance:Spot 11:1
Battery Life Typ.18, min 14 hours continuous use
Dimensions 175.2 x 39.0 x 71.9mm
Weight 179 grams including batteries (AAA*2pcs)
** The thermometer will automatically shut off if left idle for more than 15sec.
Made in Taiwan
1. Simply aim the thermometer at the measure target with Lens (
4
) and press
Meas. key (
6
) to display the surface temperature.
2. During the measurement, the MAX reading will be displayed beside the
icon.
3. The Distance:Spot is 11:1. Please make sure the target area is within the field
of view.
Measurement Range
-60 to +500
o
C (-76 to +932
o
F)
Operating Range 0~50°C (32~122°F)
Accuracy, (Tobj=15-35°C,Tamb=25°C) +/-1.0°C (1.8°F)
Accuracy
(Tobj=-33-500°C,Tamb=23 +/- 3°C)
+/-2% of reading or 2°C (4°F) whichever is greater
Emissivity 0.95 fixed
Resolution (-9.9~199.9°C) 0.1°C/0.1°F
Response Time (90%) 1sec
Distance:Spot 11:1
Battery Life Typ.18, min 14 hours continuous use
Dimensions 175.2 x 39.0 x 71.9mm
Weight 179 grams including batteries (AAA*2pcs)
** The thermometer will automatically shut off if left idle for more than 15sec.
Made in Taiwan
Infrared Food Safety Thermometer – Operating Instructions
I.R.F.S.
T
T
N
N
4
4
0
0
3
3
/
/
T
T
N
N
4
4
0
0
3
3
L
L
T
T
h
h
e
e
r
r
m
m
o
o
m
m
e
e
t
t
e
e
r
r
O
O
p
p
e
e
r
r
a
a
t
t
i
i
n
n
g
g
I
I
n
n
s
s
t
t
r
r
u
u
c
c
t
t
i
i
o
o
n
n
s
s
Model: TN403, TN403L (with Laser).
The thermometer is a non-contact infrared thermometer, and always with Real-Time Maximum (MAX) data.
Please remember to keep away from children and don’t use it for safety related applications.
(Default Screen)
ADD VALUE:
o
C or
o
F
Press Mode key (
2
) for
o
C or
o
F transferred.
:
LCD Backlight: always on.
:
ClassII Laser: always enable (only for TN403L)
EMC/RFI
Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of
approximately 3 volts per meter, but the performance of the instrument will not be permanently affected.
* Note: Under the electromagnetic field of 3V/m from 350 to 550MHZ, the maximum error is 8°C (14.4°F).
A new way to measure temperature
Radiant Innovation Inc. Http://www.ZyTemp.com
1F, No.3, Industrial East 9
th
Road, Science-Based Industrial Park,
HsinChu, Taiwan 300.
CAUTION
1. WHEN DEVICE IS IN USE, DO NOT LOOK DIRECTLY INTO THE LASER BEAM–PERMANENT EYE DAMAGE
MAY RESULT.
2. USE EXTREME CAUTION WHEN OPERATING THE LASER.
3. NEVER POINT THE DEVICE TOWARDS ANYONE’S EYES.
4. KEEP OUT OF REACH OF ALL CHILDREN.
STORAGE & CLEANING
The sensor lens is the most delicate part of the thermometer. The lens should be kept clean at all times, care should
be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol. Allowing the
lens to fully dry before using the thermometer. Do not submerge any part of the thermometer. The thermometer
should be stored at room temperature between –20 to +65°C (-4~149°F).
LCD ERROR MESSAGES
The thermometer incorporates visual diagnostic messages as follows:
‘Er2’ is displayed when the thermometer is exposed to rapid changes in the ambient temperature.
‘Er3’ is displayed when the ambient temperature exceeds 0
o
C(32°F) or +50
o
C (122°F).
The thermometer should be allowed plenty of time (minimum 30 minutes) to stabilize to the
working/room temperature.
For all other error messages it is necessary to reset the thermometer. To reset it, turn the
instrument off, remove the battery and wait for a minimum of one minute, reinsert the battery and
turn on. If the error message remains please contact the Service Department for further
assistance.
BATTERIES
The thermometer incorporates visual low battery indication as follows:
‘Battery OK’: measurements
are possible
‘Battery Low’: battery needs to be
replaced, measurements are still possible
‘Battery Exhausted’: measurements
are not possible
When the ‘Low Battery’ icon indicates the battery is low, the battery should be replaced immediately with AAA,
1.5V batteries. Please note: It is important to turn the instrument off before replacing the battery otherwise the
thermometer may malfunction. Dispose of used battery promptly and keep away from children.
SPECIFICATION
Model TN403, TN403L (with Laser)
Measurement Range
-60 to +500
o
C (-76 to +932
o
F)
Operating Range 0~50°C (32~122°F)
Accuracy, (Tobj=15-35°C,Tamb=25°C) +/-1.0°C (1.8°F)
Accuracy
(Tobj=-33-500°C,Tamb=23 +/- 3°C)
+/-2% of reading or 2°C (4°F) whichever is greater
Emissivity 0.95 fixed
Resolution (-9.9~199.9°C) 0.1°C/0.1°F
Response Time (90%) 1sec
Distance:Spot 11:1
Battery Life Typ.18, min 14 hours continuous use
Dimensions 175.2 x 39.0 x 71.9mm
Weight 179 grams including batteries (AAA*2pcs)
** The thermometer will automatically shut off if left idle for more than 15sec.
Made in Taiwan
1. Simply aim the thermometer at the measure target with Lens (
4
) and press
Meas. key (
6
) to display the surface temperature.
2. During the measurement, the MAX reading will be displayed beside the
icon.
3. The Distance:Spot is 11:1. Please make sure the target area is within the field
of view.
T
T
N
N
4
4
0
0
3
3
/
/
T
T
N
N
4
4
0
0
3
3
L
L
T
T
h
h
e
e
r
r
m
m
o
o
m
m
e
e
t
t
e
e
r
r
O
O
p
p
e
e
r
r
a
a
t
t
i
i
n
n
g
g
I
I
n
n
s
s
t
t
r
r
u
u
c
c
t
t
i
i
o
o
n
n
s
s
Model: TN403, TN403L (with Laser).
The thermometer is a non-contact infrared thermometer, and always with Real-Time Maximum (MAX) data.
Please remember to keep away from children and don’t use it for safety related applications.
(Default Screen)
ADD VALUE:
o
C or
o
F
Press Mode key (
2
) for
o
C or
o
F transferred.
:
LCD Backlight: always on.
:
ClassII Laser: always enable (only for TN403L)
EMC/RFI
Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of
approximately 3 volts per meter, but the performance of the instrument will not be permanently affected.
* Note: Under the electromagnetic field of 3V/m from 350 to 550MHZ, the maximum error is 8°C (14.4°F).
A new way to measure temperature
Radiant Innovation Inc. Http://www.ZyTemp.com
1F, No.3, Industrial East 9
th
Road, Science-Based Industrial Park,
HsinChu, Taiwan 300.
CAUTION
1. WHEN DEVICE IS IN USE, DO NOT LOOK DIRECTLY INTO THE LASER BEAM–PERMANENT EYE DAMAGE
MAY RESULT.
2. USE EXTREME CAUTION WHEN OPERATING THE LASER.
3. NEVER POINT THE DEVICE TOWARDS ANYONE’S EYES.
4. KEEP OUT OF REACH OF ALL CHILDREN.
STORAGE & CLEANING
The sensor lens is the most delicate part of the thermometer. The lens should be kept clean at all times, care should
be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol. Allowing the
lens to fully dry before using the thermometer. Do not submerge any part of the thermometer. The thermometer
should be stored at room temperature between –20 to +65°C (-4~149°F).
LCD ERROR MESSAGES
The thermometer incorporates visual diagnostic messages as follows:
‘Er2’ is displayed when the thermometer is exposed to rapid changes in the ambient temperature.
‘Er3’ is displayed when the ambient temperature exceeds 0
o
C(32°F) or +50
o
C (122°F).
The thermometer should be allowed plenty of time (minimum 30 minutes) to stabilize to the
working/room temperature.
For all other error messages it is necessary to reset the thermometer. To reset it, turn the
instrument off, remove the battery and wait for a minimum of one minute, reinsert the battery and
turn on. If the error message remains please contact the Service Department for further
assistance.
BATTERIES
The thermometer incorporates visual low battery indication as follows:
‘Battery OK’: measurements
are possible
‘Battery Low’: battery needs to be
replaced, measurements are still possible
‘Battery Exhausted’: measurements
are not possible
When the ‘Low Battery’ icon indicates the battery is low, the battery should be replaced immediately with AAA,
1.5V batteries. Please note: It is important to turn the instrument off before replacing the battery otherwise the
thermometer may malfunction. Dispose of used battery promptly and keep away from children.
SPECIFICATION
Model TN403, TN403L (with Laser)
Measurement Range
-60 to +500
o
C (-76 to +932
o
F)
Operating Range 0~50°C (32~122°F)
Accuracy, (Tobj=15-35°C,Tamb=25°C) +/-1.0°C (1.8°F)
Accuracy
(Tobj=-33-500°C,Tamb=23 +/- 3°C)
+/-2% of reading or 2°C (4°F) whichever is greater
Emissivity 0.95 fixed
Resolution (-9.9~199.9°C) 0.1°C/0.1°F
Response Time (90%) 1sec
Distance:Spot 11:1
Battery Life Typ.18, min 14 hours continuous use
Dimensions 175.2 x 39.0 x 71.9mm
Weight 179 grams including batteries (AAA*2pcs)
** The thermometer will automatically shut off if left idle for more than 15sec.
Made in Taiwan
1. Simply aim the thermometer at the measure target with Lens (
4
) and press
Meas. key (
6
) to display the surface temperature.
2. During the measurement, the MAX reading will be displayed beside the
icon.
3. The Distance:Spot is 11:1. Please make sure the target area is within the field
of view.
T
T
N
N
4
4
0
0
3
3
/
/
T
T
N
N
4
4
0
0
3
3
L
L
T
T
h
h
e
e
r
r
m
m
o
o
m
m
e
e
t
t
e
e
r
r
O
O
p
p
e
e
r
r
a
a
t
t
i
i
n
n
g
g
I
I
n
n
s
s
t
t
r
r
u
u
c
c
t
t
i
i
o
o
n
n
s
s
Model: TN403, TN403L (with Laser).
The thermometer is a non-contact infrared thermometer, and always with Real-Time Maximum (MAX) data.
Please remember to keep away from children and don’t use it for safety related applications.
(Default Screen)
ADD VALUE:
o
C or
o
F
Press Mode key (
2
) for
o
C or
o
F transferred.
:
LCD Backlight: always on.
:
ClassII Laser: always enable (only for TN403L)
EMC/RFI
Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of
approximately 3 volts per meter, but the performance of the instrument will not be permanently affected.
* Note: Under the electromagnetic field of 3V/m from 350 to 550MHZ, the maximum error is 8°C (14.4°F).
A new way to measure temperature
Radiant Innovation Inc. Http://www.ZyTemp.com
1F, No.3, Industrial East 9
th
Road, Science-Based Industrial Park,
HsinChu, Taiwan 300.
CAUTION
1. WHEN DEVICE IS IN USE, DO NOT LOOK DIRECTLY INTO THE LASER BEAM–PERMANENT EYE DAMAGE
MAY RESULT.
2. USE EXTREME CAUTION WHEN OPERATING THE LASER.
3. NEVER POINT THE DEVICE TOWARDS ANYONE’S EYES.
4. KEEP OUT OF REACH OF ALL CHILDREN.
STORAGE & CLEANING
The sensor lens is the most delicate part of the thermometer. The lens should be kept clean at all times, care should
be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol. Allowing the
lens to fully dry before using the thermometer. Do not submerge any part of the thermometer. The thermometer
should be stored at room temperature between –20 to +65°C (-4~149°F).
LCD ERROR MESSAGES
The thermometer incorporates visual diagnostic messages as follows:
‘Er2’ is displayed when the thermometer is exposed to rapid changes in the ambient temperature.
‘Er3’ is displayed when the ambient temperature exceeds 0
o
C(32°F) or +50
o
C (122°F).
The thermometer should be allowed plenty of time (minimum 30 minutes) to stabilize to the
working/room temperature.
For all other error messages it is necessary to reset the thermometer. To reset it, turn the
instrument off, remove the battery and wait for a minimum of one minute, reinsert the battery and
turn on. If the error message remains please contact the Service Department for further
assistance.
BATTERIES
The thermometer incorporates visual low battery indication as follows:
‘Battery OK’: measurements
are possible
‘Battery Low’: battery needs to be
replaced, measurements are still possible
‘Battery Exhausted’: measurements
are not possible
When the ‘Low Battery’ icon indicates the battery is low, the battery should be replaced immediately with AAA,
1.5V batteries. Please note: It is important to turn the instrument off before replacing the battery otherwise the
thermometer may malfunction. Dispose of used battery promptly and keep away from children.
SPECIFICATION
Model TN403, TN403L (with Laser)
Measurement Range
-60 to +500
o
C (-76 to +932
o
F)
Operating Range 0~50°C (32~122°F)
Accuracy, (Tobj=15-35°C,Tamb=25°C) +/-1.0°C (1.8°F)
Accuracy
(Tobj=-33-500°C,Tamb=23 +/- 3°C)
+/-2% of reading or 2°C (4°F) whichever is greater
Emissivity 0.95 fixed
Resolution (-9.9~199.9°C) 0.1°C/0.1°F
Response Time (90%) 1sec
Distance:Spot 11:1
Battery Life Typ.18, min 14 hours continuous use
Dimensions 175.2 x 39.0 x 71.9mm
Weight 179 grams including batteries (AAA*2pcs)
** The thermometer will automatically shut off if left idle for more than 15sec.
Made in Taiwan
1. Simply aim the thermometer at the measure target with Lens (
4
) and press
Meas. key (
6
) to display the surface temperature.
2. During the measurement, the MAX reading will be displayed beside the
icon.
3. The Distance:Spot is 11:1. Please make sure the target area is within the field
of view.
Typ. 180, min 140 hours continuous use
switching.
0.97 Fixed
enabled.
12:1
-55 to +280°C (-67 to 536°F)
<0°C=±1°C (±2°F) ±0.1 degree/degree
>+65°C (149°F)=1.5% of reading
0 to +65°C=± 1°C (2°F)
Tobj=0 to 65°C, Tamb=23±2°C
Tamb=23±2°C
12:1
T
T
N
N
4
4
0
0
3
3
/
/
T
T
N
N
4
4
0
0
3
3
L
L
T
T
h
h
e
e
r
r
m
m
o
o
m
m
e
e
t
t
e
e
r
r
O
O
p
p
e
e
r
r
a
a
t
t
i
i
n
n
g
g
I
I
n
n
s
s
t
t
r
r
u
u
c
c
t
t
i
i
o
o
n
n
s
s
Model: TN403, TN403L (with Laser).
The thermometer is a non-contact infrared thermometer, and always with Real-Time Maximum (MAX) data.
Please remember to keep away from children and don’t use it for safety related applications.
(Default Screen)
ADD VALUE:
o
C or
o
F
Press Mode key (
2
) for
o
C or
o
F transferred.
:
LCD Backlight: always on.
:
ClassII Laser: always enable (only for TN403L)
EMC/RFI
Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of
approximately 3 volts per meter, but the performance of the instrument will not be permanently affected.
* Note: Under the electromagnetic field of 3V/m from 350 to 550MHZ, the maximum error is 8°C (14.4°F).
A new way to measure temperature
Radiant Innovation Inc. Http://www.ZyTemp.com
1F, No.3, Industrial East 9
th
Road, Science-Based Industrial Park,
HsinChu, Taiwan 300.
CAUTION
1. WHEN DEVICE IS IN USE, DO NOT LOOK DIRECTLY INTO THE LASER BEAM–PERMANENT EYE DAMAGE
MAY RESULT.
2. USE EXTREME CAUTION WHEN OPERATING THE LASER.
3. NEVER POINT THE DEVICE TOWARDS ANYONE’S EYES.
4. KEEP OUT OF REACH OF ALL CHILDREN.
STORAGE & CLEANING
The sensor lens is the most delicate part of the thermometer. The lens should be kept clean at all times, care should
be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol. Allowing the
lens to fully dry before using the thermometer. Do not submerge any part of the thermometer. The thermometer
should be stored at room temperature between –20 to +65°C (-4~149°F).
LCD ERROR MESSAGES
The thermometer incorporates visual diagnostic messages as follows:
‘Er2’ is displayed when the thermometer is exposed to rapid changes in the ambient temperature.
‘Er3’ is displayed when the ambient temperature exceeds 0
o
C(32°F) or +50
o
C (122°F).
The thermometer should be allowed plenty of time (minimum 30 minutes) to stabilize to the
working/room temperature.
For all other error messages it is necessary to reset the thermometer. To reset it, turn the
instrument off, remove the battery and wait for a minimum of one minute, reinsert the battery and
turn on. If the error message remains please contact the Service Department for further
assistance.
BATTERIES
The thermometer incorporates visual low battery indication as follows:
‘Battery OK’: measurements
are possible
‘Battery Low’: battery needs to be
replaced, measurements are still possible
‘Battery Exhausted’: measurements
are not possible
When the ‘Low Battery’ icon indicates the battery is low, the battery should be replaced immediately with AAA,
1.5V batteries. Please note: It is important to turn the instrument off before replacing the battery otherwise the
thermometer may malfunction. Dispose of used battery promptly and keep away from children.
SPECIFICATION
Model TN403, TN403L (with Laser)
Measurement Range
-60 to +500
o
C (-76 to +932
o
F)
Operating Range 0~50°C (32~122°F)
Accuracy, (Tobj=15-35°C,Tamb=25°C) +/-1.0°C (1.8°F)
Accuracy
(Tobj=-33-500°C,Tamb=23 +/- 3°C)
+/-2% of reading or 2°C (4°F) whichever is greater
Emissivity 0.95 fixed
Resolution (-9.9~199.9°C) 0.1°C/0.1°F
Response Time (90%) 1sec
Distance:Spot 11:1
Battery Life Typ.18, min 14 hours continuous use
Dimensions 175.2 x 39.0 x 71.9mm
Weight 179 grams including batteries (AAA*2pcs)
** The thermometer will automatically shut off if left idle for more than 15sec.
Made in Taiwan
1. Simply aim the thermometer at the measure target with Lens (
4
) and press
Meas. key (
6
) to display the surface temperature.
2. During the measurement, the MAX reading will be displayed beside the
icon.
3. The Distance:Spot is 11:1. Please make sure the target area is within the field
of view.
`, UT 840 • 800.393.6434
www.thermoworks.com
Page view 0
1 2

Summary of Contents

Page 1 - I.R.F.S

TTNN440033 // TTNN440033LL TThheerrmmoommeetteerr OOppeerraattiinngg IInnssttrruuccttiioonnss Model: TN403, TN403L (with Laser). The thermometer

Page 2 - CERTIFICATE OF CONFORMANCE

CERTIFICATE OF CONFORMANCEThe manufacturer of this instrument has implemented a quality assurance system under ISO 9001:2000 certified qualit

Comments to this Manuals

No comments